Available Container Size |
N/A Pail |
Buy this LE Product! |
N/A Don't See Pricing? Register Today! |
GHS Statement |
N/A For commercial and professional use only |
Beneficial Qualities |
N/A
Superior Penetration High Load-Carrying Capacity & Friction Reduction Rust & Corrosion Protection Versatility Easy Application |
Proprietary Additive |
N/A
LE's proprietary additives are used exclusively in LE lubricants. Wirelife Monolec Penetrating Lubricant contains Monolec. Monolec® wear-reducing additive has proven its extraordinary performance in thousands of applications. An invaluable component in LE's engine oils, industrial oils and many of its other lubricants, Monolec creates a single molecular lubricating film on metal surfaces, vastly increasing film strength without affecting tolerances. It allows opposing surfaces to slide by one another, greatly reducing friction, heat and wear. |
Performance Requirements Met or Exceeded |
N/A
|
Typical Applications |
N/A
|
Caution |
N/A
Contains a combustible petroleum solvent
|
Customer Testimonials |
N/A
2001 Dutchess Quarry 2001 Macuch Steel Products Inc 2001 NCI Building Systems 2001 TFC Recycling Inc |
Relative Density @ 60ºF/60ºF, ASTM D1298 |
N/A 0.921 |
Viscosity @ 100ºC (212ºF), cSt, ASTM D445 |
N/A 15.51 |
Viscosity @ 40ºC (104ºF), cSt, ASTM D445 |
N/A 210.7 |
Viscosity @ 40ºC (104ºF) as applied, cSt |
N/A 44.76 |
Flash Point °C (°F) as applied |
N/A 96 (205) |
Pour Point °C (°F) as applied |
N/A -18 (0) |
Rust Test 4 hrs @ 60ºC (140ºF), DI H2O, ASTM D665A |
N/A Pass |
Rust Test 4 hrs @ 60ºC (140ºF), Sea H2O, ASTM D665B |
N/A Pass |
Copper Corrosion 3 hrs @ 100ºC, ASTM D130 |
N/A 1b |
Timken OK Load lbs, ASTM D2782 |
N/A 60 |
Four-Ball EP Weld Point kgf, ASTM D2783 |
N/A 400 |
Four-Ball EP Load Wear Index kgf, ASTM D2783 |
N/A 53.1 |
Four-Ball Wear @ 75ºC (167ºF), 1,200 rpm, 15 kgf, 60 minutes, mm wear, ASTM D4172 |
N/A 0.42 |
Four-Ball Wear @ 75ºC (167ºF), 1,200 rpm, 40 kgf, 60 minutes, mm wear, ASTM D4172 |
N/A 0.59 |
Falex Pin & Vee Block EP lbf, ASTM D3233 |
N/A 3,750+ lbf |
Humidity Cabinet days, ASTM D1748 |
N/A 60+ |
Salt Spray hrs, ASTM B117 |
N/A 62 hrs |
Immersion Test days, 5% saltwater |
N/A 30+ |